30″ (762 mm) length with 1-1/2″ (38 mm) diameter tubing
18-gauge Type 304 stainless steel with peened (non-slip) gripping surface
Concealed snap-flange mounting cover snaps over flange to conceal screws
Stainless steel flange continuously heliarc-welded to tubing
3-1/8″ (79 mm) O.D. flange (1/8″ thick) with (2) #10 mounting holes
22-gauge stainless steel snap-on cover, 3-3/16″ (81 mm) diameter
1-1/2″ (38 mm) wall projection meets ADA 609.3 wall clearance
Peened surface preferred for showers, pool decks, and wet-hand grip applications
Designed to meet 2010 ADA Accessibility Standards and ANSI A117.1 when properly installed
Surface mounted anchors specified separately (see ASI 3900 series)
Tested to support load in excess of 250 lbs (113.4 kg) per ADA 609.8 when properly anchored to structural backing
Manufactured by American Specialties, Inc. Yonkers, NY
ADA Standards 604.5 require grab bars in every accessible toilet stall, and 608.3 covers accessible shower compartments making them a code requirement in virtually every commercial, healthcare, and institutional facility. The ASI 3801-30P is the 30-inch peened (non-slip) variant of ASI’s 3801 Series snap-flange grab bar. At 30″ (762 mm), this is specified for shower configurations per 608.3 (vertical) or as a supplemental horizontal bar. The peened surface is mechanically textured to provide superior wet-hand grip it is the standard specification for showers, pool facilities, locker rooms, and any environment where users regularly have wet or soapy hands. The 1-1/2″ (38 mm) diameter satisfies ADA 609.2 graspability requirements. As an authorized ASI distributor with a Low Price Guarantee, carries the full 3801 line in both peened and satin finishes.
Concealed Snap-Flange Mounting: A stainless steel flange is continuously heliarc-welded to the bar tubing, then a 22-gauge stainless steel cover (3-3/16″ / 81 mm diameter) snaps down over the flange to conceal the mounting screws. The result: a clean, professional appearance with no exposed fasteners and improved tamper resistance the standard specification for commercial and institutional washrooms.
Type 304 Stainless Steel Built for Commercial Use: The 18-gauge Type 304 stainless tubing resists corrosion, hides fingerprints, and is easy to maintain with mild detergent and standard stainless steel cleaning practices (avoid bleach, chlorides, and abrasive cleaners, which can pit stainless surfaces over time). Type 304 is the industry-standard alloy for commercial restrooms, healthcare facilities, and institutional environments.
Peened Surface Specified for Wet-Hand Grip: The peened (textured) surface is mechanically pebbled to provide superior grip when hands are wet or soapy. It is the standard specification for shower compartments per ADA 608.3, pool facility restrooms, locker rooms, and any environment with frequent wet-hand use. Underneath the texture, the bar is identical Type 304 stainless steel only the surface finish changes.
Mid-Length Configuration Bar: At 30″ (762 mm), this length is specified for shower configurations per 608.3 (vertical or horizontal), supplemental support positions, and applications between standard ADA toilet bar lengths.
Installation Requires Structural Backing: Mounting hardware is not included ASI specifies installation with (2) #10 self-threading flat or oval head screws (or other fasteners suitable for the substrate) per flange. Anchors are sold separately as the ASI 3900 Series. All grab bars must be anchored into structural in-wall backing per local building codes never into drywall alone. The bar must be installed so the top is between 33″36″ above the finished floor (AFF) for ADA compliance.
| ASI 3801-30P | Bobrick B-6806 | |
|---|---|---|
| Diameter | 1-1/2″ (38 mm) | 1-1/2″ (38 mm) |
| Tubing gauge | 18-gauge | 18-gauge |
| Material | Type 304 stainless steel | Type 304 stainless steel |
| Finish | Peened (non-slip) | Peened (non-slip) |
| Mounting system | Concealed snap-flange (welded flange + snap cover) | Concealed mounting |
| Mounting hardware | Not included (3900 series anchors sold separately) | Not included |
| ADA design compliance | Designed for 609.2, 609.3 | Designed for 609.2, 609.3 |
| Cross-finish version | 3801 series (satin) | B-6806 series (satin) |
The 3801-30 (satin) is the standard choice for commercial restrooms, offices, healthcare corridors, and general-purpose applications where appearance is a priority. Both versions are identical in diameter, gauge, flange, and structural construction.
Want a slimmer profile? See the 3701-30P same length and finish, with a 1-1/4″ diameter for offices, light institutional settings, and applications where a smaller profile is specified. Both diameters fully satisfy ADA 609.2 graspability requirements.
Does this grab bar come with mounting hardware? No mounting hardware is not included. ASI specifies installation with (2) #10 self-threading flat or oval head screws per flange (or other fasteners suitable for the substrate). Anchors are sold separately as the ASI 3900 Series. All grab bars must be anchored into structural in-wall backing per local building codes never into drywall alone.
Is the ASI 3801-30P ADA compliant when properly installed? Yes when properly installed. The 1-1/2″ (38 mm) diameter meets ADA 609.2 graspability requirements (1-1/4″ to 2″ allowable range), and the 1-1/2″ (38 mm) wall projection meets 609.3 wall clearance. When mounted with the top of the bar between 33″36″ above the finished floor (AFF) and anchored into structural backing per the 2010 ADA Accessibility Standards and ANSI A117.1, this bar is designed to satisfy ADA accessibility requirements. Tested to support a load in excess of 250 lbs (113.4 kg) per ADA 609.8.
Where would a 12-inch / 18-inch / 24-inch / 30-inch grab bar typically be installed? Shorter grab bars like the 30-inch length are commonly used as vertical grab bars for shower transfer assist (per 608.3), as supplemental support bars above primary ADA toilet stall bars, or in tight side-wall positions where the standard 42″/36″ ADA bars won’t fit. ADA 604.5 specifies minimum lengths only for primary toilet stall bars (42″ side-wall, 36″ rear-wall) shorter bars serve supplemental or specialty roles. Verify required length and orientation against your applicable building code.
What is the difference between ASI 3700 and ASI 3800 Series grab bars? The ASI 3800 Series has a 1-1/2″ (38 mm) diameter the standard choice for healthcare facilities, high-traffic commercial environments, and projects where maximum grip surface is specified. The ASI 3700 Series is the same construction with a 1-1/4″ (32 mm) diameter preferred for offices, light institutional settings, and applications where a slimmer profile is desired. Both diameters fully satisfy ADA 609.2 graspability requirements (allowable range is 1-1/4″ to 2″).
When should I specify a peened grab bar instead of satin? Peened is the standard specification for any environment where users regularly have wet or soapy hands: shower compartments (per ADA 608.3 best practice), pool facility restrooms, locker rooms, spa and aquatic centers, and prison/correctional facilities. The mechanically textured surface significantly improves grip when wet. For dry restroom environments, the satin version is the standard architectural specification.
Can this bar be mounted horizontally, vertically, or at an angle? Straight ASI snap-flange grab bars are commonly installed horizontally, vertically, or at an angle depending on the application and code requirement. ADA 604.5 specifies horizontal bars for toilet applications; 608.3 covers shower orientations (which include vertical grab bars for transfer assist). Verify the required orientation and mounting heights with your applicable building code and the ASI technical data sheet for your specific SKU before installation.
30″ (762 mm) straight grab bar with a 1-1/2″ (38 mm) diameter, constructed from 18-gauge Type 304 peened-finish stainless steel. Features concealed snap-flange mounting with welded flanges and snap-on covers. ADA-compliant per 609.2 (graspability) and 609.3 (wall clearance). Installation hardware sold separately (ASI 3900 series anchors). View the full ASI 3801 Series (1-1/2″ Diameter) for all available lengths and finishes.
{ “@context”: “https://schema.org”, “@type”: “FAQPage”, “mainEntity”: [ { “@type”: “Question”, “name”: “Does this grab bar come with mounting hardware?”, “acceptedAnswer”: { “@type”: “Answer”, “text”: “No mounting hardware is not included. ASI specifies installation with (2) #10 self-threading flat or oval head screws per flange (or other fasteners suitable for the substrate). Anchors are sold separately as the ASI 3900 Series. All grab bars must be anchored into structural in-wall backing per local building codes never into drywall alone.” } }, { “@type”: “Question”, “name”: “Is the ASI 3801-30P ADA compliant when properly installed?”, “acceptedAnswer”: { “@type”: “Answer”, “text”: “Yes when properly installed. The 1-1/2″ (38 mm) diameter meets ADA 609.2 graspability requirements (1-1/4″ to 2″ allowable range), and the 1-1/2″ (38 mm) wall projection meets 609.3 wall clearance. When mounted with the top of the bar between 33″36″ above the finished floor (AFF) and anchored into structural backing per the 2010 ADA Accessibility Standards and ANSI A117.1, this bar is designed to satisfy ADA accessibility requirements. Tested to support a load in excess of 250 lbs (113.4 kg) per ADA 609.8.” } }, { “@type”: “Question”, “name”: “Where would a 12-inch / 18-inch / 24-inch / 30-inch grab bar typically be installed?”, “acceptedAnswer”: { “@type”: “Answer”, “text”: “Shorter grab bars like the 30-inch length are commonly used as vertical grab bars for shower transfer assist (per 608.3), as supplemental support bars above primary ADA toilet stall bars, or in tight side-wall positions where the standard 42″/36″ ADA bars won’t fit. ADA 604.5 specifies minimum lengths only for primary toilet stall bars (42″ side-wall, 36″ rear-wall) shorter bars serve supplemental or specialty roles. Verify required length and orientation against your applicable building code.” } }, { “@type”: “Question”, “name”: “What is the difference between ASI 3700 and ASI 3800 Series grab bars?”, “acceptedAnswer”: { “@type”: “Answer”, “text”: “The ASI 3800 Series has a 1-1/2″ (38 mm) diameter the standard choice for healthcare facilities, high-traffic commercial environments, and projects where maximum grip surface is specified. The ASI 3700 Series is the same construction with a 1-1/4″ (32 mm) diameter preferred for offices, light institutional settings, and applications where a slimmer profile is desired. Both diameters fully satisfy ADA 609.2 graspability requirements (allowable range is 1-1/4″ to 2″).” } }, { “@type”: “Question”, “name”: “When should I specify a peened grab bar instead of satin?”, “acceptedAnswer”: { “@type”: “Answer”, “text”: “Peened is the standard specification for any environment where users regularly have wet or soapy hands: shower compartments (per ADA 608.3 best practice), pool facility restrooms, locker rooms, spa and aquatic centers, and prison/correctional facilities. The mechanically textured surface significantly improves grip when wet. For dry restroom environments, the satin version is the standard architectural specification.” } }, { “@type”: “Question”, “name”: “Can this bar be mounted horizontally, vertically, or at an angle?”, “acceptedAnswer”: { “@type”: “Answer”, “text”: “Straight ASI snap-flange grab bars are commonly installed horizontally, vertically, or at an angle depending on the application and code requirement. ADA 604.5 specifies horizontal bars for toilet applications; 608.3 covers shower orientations (which include vertical grab bars for transfer assist). Verify the required orientation and mounting heights with your applicable building code and the ASI technical data sheet for your specific SKU before installation.” } } ]}
Shopping Cart
CloseYour cart is currently empty.